Chemical Permeation Chart for Protective Suits
The information below shows the breadkthrough times of a variety of protective clothing materials against 25 common chemicals. You should also review the material's physical properties to determine if it can withstand the physical hazards environment and select the material which best meets or exceeds the application requirements.
 
MAR-MAC
Ultra-Pro Commander
KAPPLER®
Responder
Dupont® Tychem®
10,000
KAPPLER® CPF IV
Dupont® Tychem®
9400
KAPPLER® CPF III
KAPPLER®
CPF II
Acetone
<480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
12    3.2
Acetonitrile
<480   ND
>480   ND
>480   ND
>480   ND
>480   ND
7    0.78
42    0.72
Ammonia Gas
<480   ND
>480   ND
>480   ND
>480   ND
47    0.4
12    1.4
------ NT
Carbon Disulfide
<480   ND
>480   ND
>480   ND
>480   ND
>480   ND
16    0.51
4 >10.0
Chlorine Gas
<480   ND
>480   ND
>480   ND
------ NT
>480   ND
>480   ND
>480   ND
Diethylamine
<480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
14 >10.0
Dimethylformamide
>480   ND
>480   ND
>480   ND
>480   ND
226   1.7
>480   ND
95    0.11
Ethyl Acetate
<480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
28    0.95
Hexane
<480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
10    0.28
Hydrofluoric Acid 48% 
<480   ND
>180   ND
------ NT
>480   ND
NT
180   0.86
>480   ND
Hydrogen Chloride Gas
>180   ND
>480   ND
>480   ND
------ NT
>480   ND
------ NT
------ NT
Hydrogen Cyanide Gas
>480   ND
>180   ND
------ NT
------ NT
NT
------ NT
------ NT
Hydrogen Fluoride Gas
>480   ND
>440   0.1
------ NT
330   0.1
NT
------ NT
------ NT
Methylene Chloride
>480   ND
>480   ND
>480   ND
------ NT
>480   ND
------ NT
------ NT
Ethylene Oxide Gas
>180   ND
>480   ND
>480   ND
------ NT
>480   ND
------ NT
------ NT
Hydrazine
>480   ND
>480   ND
------ NT
>480   ND
NT
------ NT
437   0.2
Nitrobenzene
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
205   3.0
Nitric Acid, Red Fuming
>480   ND
>180   ND
------ NT
------ NT
------ NT
------ NT
------ NT
Sodium Hydroxide 50%
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
Sulfuric Acid
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
Phosgene Gas
>480   ND
>480   ND
------ NT
------ NT
------ NT
------ NT
------ NT
Tetrachloroethylene
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
10    >20
Tetrahydrofuran
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
4    10.0
Toluene
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
>480   ND
4    39.0
Permeation: Rate by which a chemical can pass through the suit material on a molecular level through the process of absorption, diffusion, and desorption. 

Breakthrough Time: Time elapsed between initial chemical contact of the suit surface and detection of the chemical inside the suit.

* 1st number indicates breakthrough time in minutes.
* 2nd number indicates steady state permeation rate in UG/CM2/MIN

ND = None Detected
NR = Not Recommended
NT = Not Tested